Floor build-up and room height calculator

Enter the shell height or today’s clear height and choose a floor build-up. The calculator shows the clear room height, the window sill above the finished floor level (FFL) and the clear passage of the door.

I know
From the top of the structural slab (SFL) to the underside of the slab above
Floor build-up
Ceiling finish
Bottom of the window opening in the shell
Height of the door’s rough opening

Clear room height

2.795 m

Shell height 2.95 m, less 14 cm floor build-up and 1.5 cm ceiling

  • ✓ At least 2.40 m, the German guideline for habitable rooms
  • ✓ Sill 0.90 m above the finished floor (guideline at least 0.80 m)
  • ✓ Clear door passage 2.01 m from FFL (guideline 2.00 m)

The build-up weighs about 148 kg/m² and is ready for covering after roughly 9 weeks.

Open the period apartment example with its floor build-up in RoomPlanning

How the calculator works

The clear room height is the shell height less the floor build-up less the ceiling finish. The floor build-up is everything between the structural floor (SFL, top of the slab) and the finished floor (FFL): levelling, insulation, impact sound insulation, underfloor heating, screed and covering. If you only know today’s clear height, the calculator works back to the shell height it needs.

The six standard build-ups are guideline values from freely available German sources: heated screed 65 mm (16 mm pipe, 45 mm cover after DIN 18560-2), cement screed without heating 45 mm, on the ground two layers of EPS 035 at 40 mm on a bitumen membrane, dry with gypsum fibre boards and heat spreaders, thin with about 15 mm thin-layer heating. Weight and readiness follow from the layers; readiness is a rule of thumb (about a week per centimetre up to 4 cm, two beyond).

Window sills and door heights count from the finished floor. When a refurbishment raises the floor, the sill drops by exactly the build-up. For habitable rooms the German model building code (§ 47 MBO) names 2.40 m clear height, which does not apply there to residential buildings of classes 1 and 2; the state code decides. Sills are 0.80 to 0.90 m high depending on the state.

Guide: planning the floor build-up, FFL, structural floor and room height

Results are guide values for planning and do not replace professional planning or measuring on site.

Frequently asked questions

How thick is a floor build-up with underfloor heating?

In a new build with heated screed about 14 cm: covering 15 mm, heated screed 65 mm, system board 30 mm and insulation 30 mm. On a ground slab with 80 mm insulation and a membrane about 19.5 cm. Dry systems need about 8.5 cm, thin-layer systems on an existing screed about 2.5 cm.

Is the room height measured from the structural or the finished floor?

The clear room height counts from the finished floor level (FFL) to the underside of the finished ceiling. The shell is measured from the structural floor, for example by the bricklayer and for the window openings.

How much room height do I lose when retrofitting underfloor heating?

If the structure stays, the clear height drops by exactly the difference between the new and the old build-up. A dry system with 85 mm instead of old 24 mm boards costs 61 mm, a thin-layer system on the old screed only about 15 to 25 mm.

How high must a window sill be above the finished floor?

Depending on the German state 0.80 to 0.90 m, more with a large fall height. When a refurbishment raises the floor, the sill drops by the same amount; then a railing or fall protection in the window is often needed.

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan