Plan a smart home: KNX, radio, function list and roller shutters on the floor plan
Last updated: 16 November 2026
Try it right away
Free in the browser; try it without an account. To save, export and share, create a free account.A smart home is best planned before the walls are plastered: where do buttons and presence detectors go, which light and which roller shutter hangs on which actuator, where do bus cable and conduits run, and where is the hub? In RoomPlanning you put all of it straight into your floor plan, on the Network & smart home layer. From it come the function list with the actuator channels and the equipment value 1plus to 3plus after the German guideline RAL-RG 678. Drawing, control relations, hints and the function list in the editor are free; the KNX check and the exports come with Premium.

How to plan your smart home in RoomPlanning
- Draw the floor plan. Draw walls, rooms, doors and windows, or open a template (Drawing walls). Name the rooms, such as living room, kitchen or hallway.
- Choose the building system. In the Smart home section choose none, prepared (conduits), KNX, radio or mixed.
- Place devices. With the Network & smart home tool you place push buttons, blind buttons, room control units, presence and motion detectors, window contacts, a weather station, actuators in the board, a hub or border router, cameras, a door intercom and speakers.
- Set control relations. In the Device section, pick under Controls which lights, sockets, shutters or heating circuits a button or sensor switches, and its function.
- Draw the bus cable. With KNX you draw the green bus cable J-Y(St)Y 2×2×0.8 from device to device; the 230 V wires run in a star from the board (Planning circuits).
- Plan the roller shutters. Windows and outer doors get a roller shutter, external venetian blind, awning, venetian or pleated blind, by hand or with a motor. A motor counts as a load; Suggest cable draws the NYM-J 5×1.5 from the button.
- Check the function list. The function list shows each control per room, its function, the devices it controls and the actuator channel. Above it you see whether your plan reaches 1plus, 2plus or 3plus.
- Mind the hints. RoomPlanning reports radio rooms without a mains-powered device, radio systems without hub or border router and 230 V devices on no circuit.
The help Smart home and function list explains it step by step. You open the templates Family house with smart home (KNX) and Period flat with a radio smart home straight in the editor.
What is free and what is Premium
| Feature | Free | Premium |
|---|---|---|
| Placing devices, control relations, bus cables, motorised roller shutters | yes | yes |
| Function list in the editor, equipment value 1plus to 3plus, radio hints | yes | yes |
| Smoke alarms by German state, camera view cones, installation view in 3D | yes | yes |
| KNX check: actuator channels, DIN-rail devices, modules, line | – | yes |
| Function list as CSV, bill of materials as PDF, Excel and CSV, equipment report | – | yes |
| Wi-Fi coverage as a heatmap and “Suggest access points” | – | yes |
KNX or radio
| Feature | KNX (bus) | Radio (Zigbee, Thread/Matter, Z-Wave, Homematic IP, EnOcean) |
|---|---|---|
| cable | green bus cable to every button and sensor | no cable of its own |
| actuators | DIN-rail devices in the board | in the box, in the device or as a smart plug |
| hub | not needed | usually needed (gateway, border router) |
| when to plan | before plastering | any time |
| limits | 64 devices and 1000 m of cable per line | range: a mains-powered device about every 10 m |
The guide Planning a smart home: KNX or radio? compares in detail what suits your house.
Guideline values for the smart home
These are guideline values from standards, manufacturer documents and common practice, not regulations.
| What | Guideline |
|---|---|
| KNX bus cable | J-Y(St)Y or YCYM 2×2×0.8, green sheath |
| KNX line | at most 64 devices, 1000 m of cable, 350 m to the power supply |
| radio repeater | a mains-powered device about every 10 m or two solid walls |
| roller shutter motor | 230 V, about 110 W, NYM-J 5×1.5 from the button to the motor |
| buttons and switches | about 105 cm above the floor |
| equipment value 1plus | minimum equipment plus preparation for building systems |
| equipment value 2plus | standard plus at least one function area with a building system |
| equipment value 3plus | comfort plus at least two function areas |
Safety: smoke alarms, cameras and door intercom
- Smoke alarms are required in all 16 German states. The assistant in RoomPlanning knows the rule of your state and puts missing alarms on the ceiling, for free (Smoke alarms, guide Smoke alarm rules in Germany).
- Cameras show their view cone on the plan, cut off at walls. If it reaches beyond the plot, RoomPlanning warns, because then the GDPR applies (Cameras, privacy and door intercom).
- Door intercom as a 2-wire bus or IP with PoE: RoomPlanning checks door and indoor stations and adds them to the bill of materials.
The network for it, with sockets, distributor and access points, you plan on Plan a network.
Frequently asked questions
Can I plan a smart home for free?
Yes. Placing devices, control relations, bus cables, roller shutters, the function list in the editor, the equipment value and the hints are free. You can try RoomPlanning without an account. Premium adds the KNX check and the exports of the lists.
What does the KNX check check?
It counts the actuator channels for switching, dimming, blinds and heating, suggests DIN-rail devices with their modules and compares them with the distribution board on the plan. Per line it checks at most 64 devices, 1000 m of bus cable and 350 m to the power supply, along your drawn bus cables.
What is a function list?
A table that names for each room every control with its function, the devices it controls and the actuator channel, for example “Button living room: switch, ceiling light, SW1.3”. Electricians and integrators work with it. RoomPlanning builds it from your control relations.
What does 2plus mean?
Under RAL-RG 678 the standard equipment (two stars) plus at least one function area with a building system, such as lighting or shading over KNX or radio. 3plus means comfort plus two function areas.
Do radio devices need cables?
Not for control, but mains-powered devices such as flush-mounted actuators and shutter motors need 230 V. In a new build, conduits and deep boxes with a neutral conductor are still worth it, so you can switch systems later.
Sources
The values are guideline values; a qualified electrician should plan, program and install the system. Read on 16 November 2026:
- KNX Topology – Chipkin
- Installationsumfang und Ausstattungswerte – Baunetz Wissen (German)
- Press release on RAL-RG 678, 20 March 2023 (PDF) – HEA (German)
- DIN 18015-4 – DIN Media
- Installationszone – Wikipedia (German)
- Rauchmelderpflicht nach Bundesland – Stiftung Warentest (German)
- CJEU, judgment C-212/13 (Ryneš) – Curia