Plan the floor build-up: finished floor, structural floor and room height online

Last updated: 16 November 2026

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan

You plan the floor build-up by deciding for every storey and every room what lies between the structural floor (SFL, the top of the slab) and the finished floor (FFL): levelling, insulation, impact sound insulation, underfloor heating, screed and covering. RoomPlanning is a free floor planner in the browser that works out the heights from it: the clear room height, the window sills above the finished floor and above the structure, the thresholds between rooms and the risers of the stairs. A section shows the layers, their thicknesses and the FFL and SFL height marks.

How to plan the floor build-up in RoomPlanning

  1. Pick a storey. In the Levels panel set the Room height (clear). It counts from the finished floor up to the underside of the slab above (Storeys, stairs and roofs).
  2. Choose a build-up. Under Floor build-up take one of the six standard build-ups or make your own with New build-up …. A dialog asks what should stay: Room heights stay (new build, the storey heights grow) or Structure stays (refurbishment, the floor rises and the rooms get lower). It shows you what changes first.
  3. Slab and construction. With a build-up the Structural slab field stands for the load-bearing slab only. Under Slab construction choose concrete or timber joists.
  4. Adjust rooms. A bathroom with tiles gets a Floor build-up of the room in the room panel. RoomPlanning shows the room's finished floor and its Clear room height and marks the threshold at the door.
  5. Check windows and doors. In the window's panel you enter the sill measured from the Storey, the Room or the Structure. Below are the head above FFL and SFL, for doors the rough opening and the clear passage height.
  6. Look at a section. A section shows every layer with its own hatch, the slab below, the FFL and SFL marks and a legend of the build-ups (Floor build-up and heights).
The editor with the ground floor: the finished floor level in each room, and on the right the build-up New build with underfloor heating (14 cm) and a section scheme of all storeys with structural and finished floor.
The floor build-up of a storey with the section scheme of all storeys.

To try it: an old flat in which you choose a refurbishment build-up with "Structure stays".

Period apartment in 3D, seen from above at an angle, furnished

Period apartment

121 m² · 8 rooms

The terms

TermMeaning
FFL (OKFF in German)Finished floor level. Sills, door heights, stair risers and the clear height are measured from it.
SFL (RFB in German)Structural floor level, the top of the slab or base plate. Bricklayers, concreters and window fitters work from it.
Floor build-upEverything between SFL and FFL.
Clear room heightFrom the finished floor to the underside of the finished ceiling.
Storey heightFrom finished floor to finished floor. With equal build-ups the same as from slab to slab.

The storey height is the clear height plus the ceiling finish, the slab and the build-up above it. An example for a new build: 2.50 m clear height, 1 cm plaster, 20 cm slab and 14 cm build-up make 2.85 m.

The six standard build-ups

Thicknesses are guideline values for early planning, top to bottom.

Build-upLayersTotal
New build with underfloor heatingParquet 15, heated cement screed 65, system board 30, EPS insulation 30140 mm
New build without underfloor heatingParquet 15, cement screed 45, impact sound EPS-T 20, EPS insulation 30110 mm
On the ground slab with underfloor heatingTiles 15, heated screed 65, system board 30, insulation 2 × 40, sealing 5195 mm
Dry retrofit with underfloor heatingVinyl 10, gypsum fibre dry screed 25, dry heating system 30, levelling fill 2085 mm
Thin retrofit on the existing screedCovering 10, thin-layer heating 15 on the existing screed25 mm new
Unheated basementCoating 2, bonded screed 4042 mm

A standard build-up is copied into your plan when you first use it. In the build-up editor you change layers, thicknesses and materials, mark layers as Existing or Removed and see the total and the change against the existing floor at once.

Guide: the floor build-up in a refurbishment

In a refurbishment the slab and the windows are fixed. Every centimetre the new floor rises is missing somewhere else, so it pays to work out what happens before choosing a system.

  • Clear height. If the new build-up raises the floor by 6 cm, the clear height drops by 6 cm. The German model building code names 2.40 m for habitable rooms; the states differ in places, and less often applies to houses with one or two dwellings.
  • Window sills. The effective sill drops by exactly the amount the floor rises. If it ends up below about 0.80 to 0.90 m with more than a 1 m drop outside, check the fall protection your building code requires.
  • Doors. Door leaves get shorter or frames need to go up. RoomPlanning shows the clear passage height against the higher finished floor of both sides.
  • Thresholds. If the bathroom keeps its tiled build-up, there is a step to the hall. Barrier-free means at most 2 cm, and only where technically unavoidable.
  • Stairs. If the floor rises at the top or the bottom, the first or last riser gets higher or lower. For a solid stair both build-ups must be fixed before the concrete is poured.
  • Weight and moisture. On timber joist floors dry screed is the usual choice: gypsum fibre boards weigh about 30 kg/m², a wet heated screed of 65 mm about 140 kg/m² and brings water into the house.
  • Retrofitting underfloor heating. Dry systems need about 6 to 9 cm, thin-layer systems on the existing screed only 1.5 to 3 cm. The manufacturer's data rules here, not the tables of the screed standard.
  • Thermal protection. If you renew a floor towards soil, outside air or unheated rooms, the German Building Energy Act asks for a U-value of at most 0.50 W/(m²K) for that element. The act continues as the Building Modernisation Act (GModG); check the version in force with your energy consultant.

RoomPlanning shows hints on these points in the storey, room, window and stair panels, each with its source. They are guidelines and never block anything.

More in the guides Planning the floor build-up: finished floor, structural floor and room height and Retrofitting underfloor heating: build-up heights in old buildings. The floor build-up calculator works out the clear height of a room.

A house with two storeys, both with underfloor heating in the screed already. Give the shower room a build-up of its own or a storey a different one:

Detached house 140 m² in 3D, seen from above at an angle, furnished

Detached house 140 m²

143.4 m² · 13 rooms

Screed thicknesses as a guideline

ScreedGuideline
Cement screed CT-F4, unheatedabout 45 mm
Calcium sulphate flowing screed CAF-F4about 35 mm, at least 40 mm under tiles
Heated screed, pipes in the screed (type A)at least 45 mm (CT) or 40 mm (CAF) above the pipe
Gypsum fibre dry screed18 to 33 mm, ready for covering at once
Impact sound insulation20 to 35 mm

As a rule of thumb cement screed dries about one week per centimetre up to 4 cm, much slower beyond.

Frequently asked questions

What is the difference between the finished and the structural floor?

The finished floor (FFL) is the top of the floor you walk on. The structural floor (SFL) is the top of the slab below it. The distance between the two is the floor build-up.

How thick is a floor build-up with underfloor heating?

In a new build about 12 to 15 cm: covering, about 65 mm of heated screed, system board and insulation. On the ground slab more insulation comes in, then it is more like 18 to 20 cm. Dry and thin-layer systems for refurbishments are much flatter.

Where is a window sill measured from?

Usually from the finished floor. Window fitters and the structure work with the height above the structural floor. RoomPlanning shows both and converts an input in one reference into the other.

What clear room height do I need?

The German model building code names 2.40 m for habitable rooms and 2.20 m over half the area for attics. It does not apply there to residential buildings of classes 1 and 2; the law of your state or country decides.

What happens to the rooms when I change the build-up?

You decide in the dialog: if the room heights stay, the storey heights grow and the storeys above rise. If the structure stays, only the floor rises, the rooms get lower and sills and door heights drop by the same amount.

Does RoomPlanning work out quantities and costs?

Yes, with Premium: Floors, quantities and costs lists per room area, build-up, FFL, SFL, clear height and edge strip, per material area and volume with waste, plus weight, rough U-value, readiness and a cost range from guideline values or your own prices, as CSV and PDF. Floor build-ups, heights and hints stay free, and so does the floor build-up calculator.

Sources

All numbers are guideline values for early planning. The standard in force, the manufacturer's approval, the structural engineer and the energy consultant decide. Read on 15 November 2026:

Matching templates

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan

More use cases