Plan a solar PV system online – modules, shading, battery and yield

Last updated: 16 November 2026

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan

A solar PV system is best planned on a model of your house: draw the roof with its pitch and orientation, lay modules on the roof faces with edge distances, then see how much power fits and where the sun stands over the year. In RoomPlanning you put the modules straight onto the roofs you draw anyway, see the sun and shadows in 3D and, with a free account, get an estimate of the annual yield. All values are guidelines: this does not replace a professional design, a structural check or registering with the grid operator.

A house with a gable roof in 3D: the east and west faces of the roof are fully covered with dark solar modules, beside it a parking space with a car and a wallbox on the wall.
The House with photovoltaics template in 3D: 48 modules on the east and west faces of the gable roof.

How to plan your solar PV system in RoomPlanning

  1. Draw the house and the roof. Draw the outer walls and add a roof: gable, hip, shed or flat, with pitch, overhang and ridge direction (Levels, stairs and roofs). Switch on a chimney in the roof panel; modules keep their distance from it.
  2. Set the location and north. With nothing selected, the Location panel is on the right. Pick a city from the list or enter latitude and longitude. The location is stored rounded to 0.01°, about 1 km; no exact address is kept in the plan. Check the north arrow too: it decides whether a roof face points south or east.
  3. Fill the roof. On the upper floor with the roof, take the Solar PV tool (key X) and click a roof face. RoomPlanning fills it with modules, keeping a distance from eaves, ridge, verge, hips and valleys (30 cm by default) and from the chimney (50 cm). In the Solar PV panel on the right you choose the module type, portrait or landscape, the gap between modules and the edge distances.
  4. Adjust by hand. Clicking a module removes it, clicking a free spot on the roof face adds one. Fill face lays the face out again, Remove all modules clears the roof. The panel keeps count: number of modules, power in kWp and module area in m².
  5. Look at sun and shadows. In the 3D view set the light to Sun. With the sliders for date and time or the buttons 21 Mar, 21 Jun and 21 Dec you see where the sun stands at your location and where the chimney, a wing of the house or trees cast their shadows.
  6. Estimate the annual yield. With a free account, the Solar PV panel shows the estimated annual yield in kWh and the specific yield in kWh/kWp. For this RoomPlanning fetches the climate data of a typical year from PVGIS (the European Commission's Joint Research Centre) through its own server and calculates every roof face with modules in your browser.
The editor with the Solar PV tool: the covered roof faces from above in the plan, and on the right the panel with 48 modules, 21.12 kWp, 93.7 m² and an estimated annual yield of about 18,330 kWh.
The Solar PV panel counts modules, kWp and area and, with a free account, estimates the annual yield.

Step by step with pictures, from the location to the inverter and battery: Plan solar PV in the help.

To try it: a house with an east-west roof, a battery and a wallbox, its modules already in place.

House with photovoltaics in 3D, seen from above at an angle, furnished

House with photovoltaics

143.4 m² · 13 rooms

More houses with a roof are the family house with a hip roof, the 100 m² bungalow and the terraced house.

Rules of thumb for modules and yield

These are guidelines for planning (2026). What counts is the data sheet of your module and the installer's quote.

WhatGuideline
Module, half-cut cells, 1722 × 1134 mmabout 420 to 440 Wp
Module, half-cut cells, 1762 × 1134 mmabout 440 to 460 Wp
Large format, 1961 × 1134 mmabout 480 to 500 Wp
Space neededabout 4.5 to 5 m² of roof per kWp
Weight with mounting (pitched roof)about 15 kg/m², more with ballast on a flat roof
Specific yield in Germanyabout 850 to 1,100 kWh per kWp and year
East and west roofabout 80 to 90 % of a south roof with a 30 to 35° pitch
North roof at 30°about 60 to 65 % of a south roof

So 10 kWp need roughly 45 to 50 m² of roof that can be covered well. How much your roof really yields at your location is calculated more precisely by PVGIS; RoomPlanning uses the same climate data.

Distances on the roof

  • Edges. Modules usually keep 20 to 50 cm from eaves, verge and ridge. Wind loads are higher at edges and corners (wind zones under EN 1991-1-4). The mounting system's installation manual says how much distance is needed.
  • Chimney. The cleaning opening and the flue outlet must stay free, and the chimney sweep needs a way there. A guideline is 0.5 to 1 m; ask your chimney sweep.
  • Party wall of a terraced or semi-detached house. In Germany the model building code (§ 32(5) MBO, 2022 version) asks for 1.25 m, 0.5 m or no distance from the wall to the neighbour, depending on how wall and modules are built. The federal states adopted this differently, so check your state's building code. In RoomPlanning you keep this distance free with the verge distance for now, or remove the modules on that side by hand.
  • Roof load. Not every old roof carries about 15 kg/m² more. If in doubt, have the structure checked.

Registering and feeding in (Germany)

  • Grid operator. You register a solar PV system with your grid operator before it is connected; usually the installer does this.
  • Market master data register. Within one month of commissioning you enter the system and any battery in the Federal Network Agency's Marktstammdatenregister.
  • Feed-in limit. Since the Solarspitzengesetz (25 Feb 2025), new systems from 7 kWp without control via a smart metering system may feed in at most 60 % of their rated power. Anything above that you use yourself, store or it is curtailed.

Shading, battery and economics (Premium)

With Premium, RoomPlanning works your system out in more detail in the browser, again after every change:

  • Shading per module. For every module, the horizon at six points from roofs, chimneys, higher walls, trees and neighbouring houses you draw, plus the far horizon from PVGIS. A shaded module slows down its string; RoomPlanning counts the bypass diodes in a simplified way. In 2D and 3D the modules take on a colour by their loss.
  • Self-consumption and self-sufficiency. Hour by hour with the BDEW standard load profile H25 for households, scaled to your yearly consumption, plus a heat pump and an electric car at the wallbox, with surplus charging if you like. A battery charges from surplus; what is above the feed-in limit is curtailed.
  • Comparison. Your plan beside "without battery", "with battery" and "with battery and wallbox". Without a battery in the plan, RoomPlanning suggests a size after the rule of thumb of HTW Berlin: about 1 kWh per 1,000 kWh a year, at most 1.5 kWh per kWp.
  • Economics. Investment, savings, feed-in payment, running costs, degradation and an inverter replacement over 20 years: payback, levelised cost of electricity and return. The tariff comes from a dated table with a switch: EEG in force, EEG 2027 draft or your own values.
  • Strings, parts list and report. Strings automatically or by click, with checks of voltage and current at the inverter; a parts list with rails, roof hooks and clamps as CSV; everything together as a PDF report.

Drawing, sun and shadows in 3D, the hints and the annual yield as one number stay free. Tilted modules on a flat roof (facing south or east-west) come later; until then they lie flat on the roof.

Feed-in tariff in Germany (as of 15 Nov 2026)

Commissioning 1 Aug 2026 to 31 Jan 2027Partial feed-inFull feed-in
Share up to 10 kWp7.70 ct/kWh12.22 ct/kWh
Share from 10 to 40 kWp6.66 ct/kWh10.24 ct/kWh

Above 10 kWp a mixed rate applies; 15 kWp come to about 7.35 ct/kWh. The rate falls by 1 % every half year and is paid for 20 years. The government draft of the EEG 2027 has no fixed tariff for new small roof systems and limits feed-in to 50 %; it is not passed yet. RoomPlanning calculates with the EEG in force by default.

Frequently asked questions

Can I plan my solar PV system for free?

Yes. Laying out modules, sun and shadows in 3D and the plan in 2D are free in the browser, and you can try it without an account. For the estimated annual yield you need a free account, because the climate data is fetched through our server.

How many solar modules fit on my roof?

Click the roof face with the Solar tool: RoomPlanning fills it with the edge distances you set and shows the number of modules, kWp and area. Try portrait and landscape; depending on the shape of the face, one of them fits more modules. As a rule of thumb you need 4.5 to 5 m² per kWp.

How much electricity does a solar PV system produce per year?

In Germany it is about 850 to 1,100 kWh per kWp and year, depending on location, pitch and orientation, so a 10 kWp system facing south yields roughly 8,500 to 11,000 kWh. RoomPlanning calculates the value for your location and your roof faces from PVGIS climate data, without shading of single modules. It is a guideline, not a yield assessment.

Is an east-west roof worth it?

Usually yes: east and west faces yield about 80 to 90 % of a south roof and produce power in the morning and evening, when households use more. Fill both faces in RoomPlanning and compare the annual yield.

Is a home battery worth it?

The comparison in the evaluation shows it: a battery often raises self-consumption and self-sufficiency a lot, but costs about €300 to €750 per kWh. Whether it pays depends on the consumption in the evening, the electricity price and the feed-in tariff. RoomPlanning puts your plan beside a version without a battery, each with its payback. The guide Is a home battery worth it? has a worked example.

How exact is the shading analysis?

It is a guideline value: RoomPlanning calculates with a typical year from PVGIS, hour by hour, with the horizon of every module and a simplified model of the bypass diodes. Trees let light through depending on the season. For a yield report, an installer calculates with the data of the real modules.

How does RoomPlanning know where the sun is?

From the location in the Location panel, the north arrow of your plan, the date and the time. RoomPlanning calculates the sun's position with the method of the US agency NOAA. The Day, Evening and Night light settings, on the other hand, are for looks and do not show the real position of the sun.

What data goes to PVGIS?

Only the coordinates of your location rounded to 0.05°, sent from our server, not from your browser: no IP address, no account, no plan. We cache the climate data per location for everyone, so not every plan needs a new request (Privacy).

Sources

Guidelines for planning, not legal, tax or engineering advice. Read on 15 Nov 2026:

Matching templates

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan

More use cases