Plan solar PV

Step by step on a detached house: set the location, lay modules on the roof, see sun and shadows in 3D, estimate the annual yield and add an inverter and a battery. Plus shading, strings, parts list, self-consumption, economics and the PDF report.

With the Solar PV tool you lay solar modules on the roofs of your plan. In 3D you see where the sun stands at your location and where shadows fall, and with a free account RoomPlanning estimates the annual yield. This guide shows it on the Detached house 140 m² without building services (the template in the gallery has them drawn in already) with a gable roof: you cover the south side of the roof, look at the array in 3D and add an inverter and a battery in the utility room. It takes about ten minutes.

All values are guidelines. This does not replace a professional design, a structural check or registering with the grid operator.

Open the template in the editor

1. Open the template

Open the Detached house 140 m² without building services with the button above. It has two storeys and a gable roof with a 38° pitch; the ridge runs east to west, so one roof face looks due south.

The editor with the ground floor of the detached house: living and dining, kitchen, hallway with stairs, study, utility room and shower room, the terrace on the left.

2. Set the location and north

Click an empty spot with the Select tool (V) so that nothing is selected. Below the levels and the terrain on the right you then find the Location panel. Choose a city under Town, here München (Munich), or type Latitude and Longitude by hand. RoomPlanning stores the location rounded to 0.01°, about 1 km; an address is never kept in the plan.

Below is North: degrees clockwise from the top of the plan. It turns the north arrow at the top right of the plan. Check it carefully: it decides which way every roof face looks, and so the sun's position and the yield. In the template north points up, so 0°.

On the right the Location panel with the town München, latitude 48.14 and longitude 11.58, below it North 0° with a compass. At the top right of the plan the north arrow.
  1. Choose a town
  2. Or latitude and longitude
  3. North
  4. North arrow in the plan

3. Go to the upper floor and take Solar PV

The roof belongs to the top storey. So switch to Floor 1 in the Levels panel. There you see the outline of the roof dashed around the house.

Then open Solar PV under Structure on the left, or press X, and choose Continue in the floor plan at the bottom of the workspace. The Solar PV panel opens on the right with the settings for the next roof face.

The upper floor with the dashed roof outline. On the left the Solar PV tool is chosen with the key X, on the right the Solar PV panel with module type, format and edge distances.
  1. Solar PV, or key X
  2. Roof outline
  3. Settings

4. Cover the south side

Click into the lower half of the house: that is the roof face looking south. RoomPlanning fills it with modules in rows parallel to the eaves, keeping an edge free, 30 cm by default from eaves, ridge and verge. At the bottom of the panel RoomPlanning keeps count: 24 modules fit here, 10.8 kWp on 48 m².

The southern roof face in the plan is covered with three rows of eight blue modules. At the bottom of the panel: 24 modules, 10.80 kWp, 48.0 m².
  1. Modules on the south side
  2. Count, power and area

5. Module type, format and distances

The settings in the panel apply to the face clicked last. When you change one, RoomPlanning lays the face out again straight away.

  • Module type: generic presets with typical data sheet values: 420, 450 and 500 Wp, 440 Wp full black and 440 Wp glass-glass bifacial. For your quote, the data sheet of the real module counts.
  • Portrait or Landscape: depending on the shape of the face, one of them fits more modules. On this south side it is 24 in portrait and 20 in landscape.
  • Module gap between the modules and the distances to the eaves, the ridge, the verge, hips and valleys and the chimney (50 cm by default). These are guidelines; what counts is the mounting system's installation manual and your chimney sweep.
  • Fill face lays the face out again, Remove all modules clears it.
The Solar PV panel: module type 450 Wp, portrait chosen, below the module gap of 20 mm and the distances to eaves, ridge, verge, hips and valleys and chimney, at the bottom the buttons Fill face, Remove all modules and Fill all suitable faces.
  1. Module type
  2. Portrait or landscape
  3. Gap and edge distances
  4. Fill and clear

The roof gets a chimney in the roof panel: select the roof and switch on Chimney. The modules then keep their distance from it.

6. Remove and add single modules

Clicking a module removes it, clicking a free spot on the roof face adds one. That way you keep room free, for a roof window or an aerial for example. Here two modules at the top right are gone; the panel now counts 22 modules.

The south side zoomed in: two modules are missing at the top right, the roof is free there.
  1. Two modules removed with a click

7. Look at the roof in 3D

Switch to the 3D view in the bar at the top. The modules lie on the roof face, with its pitch and the distances to the edge. Under 3D view on the right, switch off Room names to keep the roof clear.

The detached house in 3D from the south-east: the dark modules lie in three rows on the red gable roof, with the gap of two modules at the top right.
  1. Modules on the roof

In the floor plan you hide and show the modules under Layers with Solar PV.

8. Sun and shadows

Under 3D view on the right, set the light to Sun. With the Date slider you pick the day, or you jump to the spring equinox and the summer and winter solstices with 21 Mar, 21 Jun and 21 Dec. The Time slider sets the hour, Play the day lets the sun travel from morning to evening. Below, the panel tells you how high the sun stands and where it comes from.

The sun stands where it really would at your location, turned by the north arrow. When it is below the horizon, it is night. That way you see whether a chimney, an extension or a tree shades the modules in winter. The other settings, Day, Evening and Night, are for looks and do not show the real position of the sun.

The 3D view on 21 December at 3 pm: the sun stands low in the south-west, the east side of the house lies in shadow. On the right the light set to Sun, below it the date, the buttons 21 Mar, 21 Jun and 21 Dec, the time and the sun's position.
  1. Light: Sun
  2. Equinox and solstices
  3. Time
  4. Height and direction of the sun

9. Estimate the annual yield

Back in 2D, take the floor plan tool again (X, then Continue in the floor plan); in the workspace the same button is in step 4 Result. Below the module count is the button Calculate annual yield. It needs a free account. RoomPlanning fetches the climate data of a typical year once per location from PVGIS, the service of the European Commission's Joint Research Centre, and calculates every roof face with modules in your browser, with its pitch and orientation. Only coordinates rounded to 0.05° go to PVGIS, from our server.

The result is the estimated annual yield in kWh and the specific yield in kWh per kWp, a guideline without shading. In Germany about 850 to 1,100 kWh per kWp and year are common, more on a steep south face in the south.

At the bottom of the Solar PV panel: 22 modules, 9.90 kWp, below it the annual yield in kWh, the yield per kWp and the source of the climate data: European Union, PVGIS.
  1. The array
  2. Annual yield and yield per kWp

Without a location the panel tells you that it needs one. If the climate data cannot be reached right now, try again later.

10. Add an inverter and a battery

Inverters and batteries are in the Furniture library (F) under Electrical & services, or through the search: PV inverter for the wall, Home battery standing on the floor and Home battery, wall hanging on the wall. Here both go on the ground floor, against the wall of the utility room.

The furniture library with a search for inverter and the PV inverter card.
  1. Search
  2. Click it, then click into the plan

Select a device. Under Energy data (typical) on the right you give it typical values: inverters with 5, 8, 10 or 15 kW, each also as a hybrid inverter for a battery, and batteries with 5, 10 or 15 kWh of usable capacity. A 10 kW hybrid inverter and a 10 kWh battery suit the almost 10 kWp on the roof.

The utility room zoomed in, the inverter and the battery against its south wall. The inverter is selected; on the right, Energy data (typical) shows Hybrid inverter 10 kW.
  1. Energy data (typical)
  2. PV inverter
  3. Home battery

The energy data stay with the device. Self-consumption, self-sufficiency and economics are in the Evaluation (Premium), further down.

Shading

RoomPlanning counts what casts shade on the modules by itself: the plan's roofs with their chimney, walls of higher storeys and trees from the catalog. The far horizon of hills and mountains comes from PVGIS.

What is not in the plan you add in the Shading panel of the solar tool:

  1. Click Neighbouring house or Tree.
  2. Click on the plan where it stands.
  3. Change width, depth and height of the house, or crown diameter, crown start and height of the tree. A deciduous tree lets more light through in winter.

In the plan, house and tree show with their height above ±0; in 3D they stand as bodies with shadows, also with the Sun light.

Evaluation (Premium)

With Premium, the Evaluation panel calculates in your browser after every change:

  • Annual yield with shading: for every module at six points, with the three bypass sub-strings of a module. Show shading on the modules colours the modules in 2D and 3D: light for hardly any loss, dark for 30 % and more.
  • Self-sufficiency and self-consumption hour by hour with the BDEW standard load profile H25, your yearly consumption and the devices of the plan: battery, wallbox with charging profile and heat pump. Their data are in the object panel under Energy data.
  • Payback with the feed-in tariff of the EEG in force and the feed-in limit.

Open evaluation shows everything in detail:

  • Overview: production and consumption per month and where the electricity goes.
  • Shading: the loss per roof face and the module that loses most.
  • Energy balance: your plan compared without battery, with battery and with wallbox. Without a battery in the plan, RoomPlanning suggests a size after the rule of thumb of HTW Berlin.
  • Economics: feed-in tariff (EEG in force, EEG 2027 draft or your own values), feed-in limit, electricity price with its yearly increase, costs of the system and the battery; investment, payback, levelised cost of electricity, return and the result year by year. Without your own prices RoomPlanning uses guideline values.
  • Strings and Parts list, see below.

Report as PDF sums it all up on a few pages: cover with the 3D picture (when the 3D view was open), assumptions, layout with strings, shading map, string plan, energy balance, economics, parts list, hints and sources.

Strings and inverters

Place an inverter from the catalog (Electrical) in the plant room. In the Strings panel of the solar tool, Assign strings automatically puts every module into a string: one MPP tracker per roof face, as many modules per string as the voltage window allows, in a snake through the rows. By hand, choose New string or Click modules and click the modules in the order they are wired.

In the plan each string runs as a coloured line through its modules, and every module carries its number, such as S1.03. The table under Strings checks the open-circuit voltage at −10 °C, the MPP voltage at 70 °C, the current at the tracker and the inverter's DC/AC ratio. These are guideline values; the data sheets decide.

Parts list

The parts list counts modules, inverters, batteries and wallboxes, mounting rails in stock lengths with connectors, roof hooks every 1.2 m, middle and end clamps, earthing clamps, the estimated solar cable, connectors and surge protection. Parts list as CSV opens in every spreadsheet. In the DXF export, modules, strings and shading bodies lie on their own layers (PV_MODULE, PV_STRING, PV_OBSTACLE).

On sheets, Add offers under Photovoltaics the PV layout plan (every roof face with modules in its true size, eaves at the bottom, with strings, module numbers and dimensions; one roof or all) and, with Premium, Key figures, strings and devices. Sheet “Photovoltaics” under Drawings puts both with the site plan on an A3 sheet. The printed electrical plan lists meter cabinet, inverter, battery and wallbox in the energy devices legend.

Hints

The Hints panel checks without a subscription: modules off the face or in the edge distance, the distance to fire wall and chimney, strings outside the voltage window, the 60 % limit from 7 kWp, batteries above 1.5 kWh per kWp, the grid operator's consent for large wallboxes, the roof load and the registration with the grid operator and in the Marktstammdatenregister. A click shows the spot. Every hint names its source and never blocks anything.

Good to know

  • On a flat roof the modules lie flat for now. Tilted rows facing south or east-west come later.
  • In the floor plan the modules lie on the roof as seen from above, with a hint of their cells.
  • When you select a roof, the panel on the right says how many modules lie on it. Plan solar PV takes you straight to the Solar PV tool from there.
  • The Shading panel (further down) counts the shading of single modules; in 3D you also see when a chimney, an extension or trees cast shadows.