Draw gas pipes

Step by step on the detached house: set up the gas appliance, add the gas network, draw pipe, riser and flue, insert the shut-off valve with TAE, check the combustion air, print the installation plan and get the material list.

With the building services you can also sketch gas pipes: from the house connection via the meter to the shut-off valve in front of every gas appliance, with height, material and fittings, in 2D and in 3D. This guide shows it on the Detached house 140 m² without building services (the template in the gallery has them drawn in already): you run a pipe from the gas meter in the utility room under the ceiling through the hallway to the gas cooker in the kitchen. It takes about ten minutes.

Open the template in the editor

1. Place the house connection and appliances

First place the fixed points from the catalog: house entry, gas meter, gas socket and the appliances such as gas cooker, hob or gas dryer, plus the flue connection if needed (Furnishing). In the example the house entry and a G4 gas meter hang on the wall of the utility room, and a gas cooker stands in the kitchen where the hob was.

With Select (V), click the gas cooker. Under Connections you see its gas connection, below it in the Gas appliance section the Appliance type: Type A – no flue (such as cooker and hob), Type B – open-flued, taking air from the room, or Type C – room-sealed with a balanced flue. Nominal load (kW) shows a guideline value from the catalog; enter the value from the rating plate or the datasheet.

The gas cooker in the kitchen is selected. On the right the gas connection G at 650 mm, the appliance type Type A – no flue (cooker) and the nominal load 10 kW.
  1. Select the gas cooker
  2. Appliance type
  3. Nominal load in kW

2. Add the gas network

The tools are in the left bar under Building services. Choose Gas pipe. In the Gas networks section on the right, Add standard networks creates the network Gas with the Pressure stage natural gas low pressure, an Operating pressure (mbar) of 23 and the Material copper. Under Add network you choose yourself:

  • Natural gas low pressure if your network operator supplies the house at low pressure (about 20 to 23 mbar in the house);
  • Natural gas medium pressure with regulator if it supplies medium pressure (over 100 mbar up to 1 bar) and a gas pressure regulator sits behind the main shut-off.

Your network operator tells you which pressure stage you have. Only materials usual for gas are offered: Steel, Steel press, Stainless steel press, Corrugated stainless steel, Copper and Multilayer (gas); PE is only for pipes in the ground.

Above it the Gas safety section shows the sentence "Planning as a sketch – installation only by registered professionals (NDAV § 13)" and what to do If you smell gas.

On the left under Building services, Gas pipe is chosen. On the right the Gas safety section and below it the gas network Gas with pressure stage natural gas low pressure, operating pressure 23 mbar and material copper.
  1. Gas pipe
  2. Gas safety
  3. The gas network

3. Draw the pipe

In the Gas pipe section on the right you choose the Network, the Routing (for example Exposed, In the wall / frame, In the floor (screed), Under the ceiling or In the ground) and the Height above floor. There are no fixed installation zones for gas, so the height belongs in the plan. In the example the pipe runs Under the ceiling.

The gas connections of house entry, meter and appliance show on the plan as dots. Click the connection of the house entry and the inlet of the meter, then start the second pipe at the outlet of the meter. Add corners with a click and end at the connection of the gas cooker or at another pipe of the same network. There the pipe snaps in and adds the vertical runs itself. Enter or a double click ends the pipe. Gas pipes are yellow, as DIN 2403 provides for fuel gases.

The gas pipe runs from the meter in the utility room through the hallway into the kitchen to the gas cooker. On the right Network Gas, Routing Under the ceiling and Height above floor 2.65 m.
  1. Network
  2. Routing
  3. Height above floor
  4. From the meter to the cooker

4. Place a gas riser

A Gas riser takes the gas vertically through several storeys, for example from the basement to the kitchen or up to the upper floor. Choose Gas riser and click on the plan where the pipe goes up. A click with Select shows From level and To level with their heights on the right. On the other storeys you connect the pipes to the riser (Levels).

A gas riser stands in the utility room. It is selected; on the right From level ground floor and To level floor 1.
  1. Gas riser
  2. From level, to level

5. Read the hints and insert the valve

In the Hints section RoomPlanning checks your sketch, for example:

  • "The shut-off valve with TAE is missing in front of the gas appliance";
  • no excess flow valve (GS) drawn;
  • no main shut-off (HAE) at the start of the network;
  • medium pressure without a gas pressure regulator in front of the meter;
  • a material that is not suitable for gas where it lies.

For the missing valve, Insert puts the shut-off valve with TAE on the pipe right in front of the appliance. A click on a hint shows the spot on the plan. Hints block nothing and replace no inspection; they are prompts for the talk with the installer.

The Hints section with the entry The shut-off valve with TAE is missing in front of the gas appliance and the button Insert below it.
  1. Hint with its source
  2. Insert

6. Place fittings

A click with Select on a gas pipe selects it. On the right you see its Material (as the network or one of its own) and under Fittings every fitting with its Distance from pipe start. On the plan it shows at that point of the pipe. Add fitting adds one of these fittings:

FittingWhat for
Shut-off valve with thermal cut-off (TAE)in front of every gas appliance; closes by itself in a fire
Shut-off valveto shut off single sections, for example in front of the meter
Main shut-off (HAE)at the end of the house connection, near the house entry
Insulating jointseparates the house pipe electrically from the network
Gas pressure regulatorwith medium pressure, lowers the pressure to low pressure
Excess flow valve (GS)at the start of the installation; closes when the flow is too high
Gas bayonet socketfor a detachable connection, typical for the cooker
Test nipplemeasuring point for the installer's tests
The gas pipe to the cooker is selected. On the right under Fittings the shut-off valve with TAE with its distance from the pipe start, below it Add fitting.
  1. Fittings of the pipe
  2. Add fitting
  3. Valve in front of the cooker

7. Legend, print and export

Gas pipes lie on the Gas layer. Beside the floor plan stands the Gas legend: for every network the length of its pipes, the number of fittings and the nominal load of the connected appliances. Under Layers you hide and show the layer, for example to print only the floor plan.

Every print and PDF of a plan with gas pipes carries the line "A sketch, not a construction design – only a registered installation company may work on gas installations (NDAV § 13)" at the bottom. The line stays with Premium too, because it is not a watermark (Drawings and export).

The ground floor with the yellow gas pipe, beside it the Gas legend with the length of the pipe, one fitting and 10 kW.

8. The gas pipes in 3D

In the 3D view, switch Building services on the right to Off, Visible (only exposed pipes) or X-ray: then you see every gas pipe in yellow, the risers through the slabs too. With the walls on Cut and Walls towards the camera see-through the view is clear.

The 3D view of the ground floor with building services on X-ray: the yellow gas pipe runs under the ceiling from the utility room through the hallway to the cooker in the kitchen.
  1. Building services: Off, Visible, X-ray

9. Draw the flue

Under Building services pick Flue. Click the boiler, water heater or stove first, then the points of the horizontal connection; a double click or Enter sets the shaft. A room-sealed boiler (type C) gets a Concentric air/flue system 80/125, an open-flued appliance a Flue pipe in a shaft. Ending in an outside wall makes it an Outside wall outlet.

On the right under Flue you set the kind, Flue pipe and Outer air pipe, the shaft, Up to storey and Through the roof. The Outlet height by guideline follows the German combustion regulations (§ 9): 40 cm above the ridge or 1 m above the roof surface, room-sealed appliances up to 50 kW with a fan 40 cm. Length and bends are listed below. In 3D the outlet stands out of the roof; sections and facades show the flue too. The district chimney sweep certifies the flue.

10. Check the combustion air

Select a room with a gas appliance: the box Combustion air shows the room volume, the load of open-flued appliances (type B) and gas cookers (type A), what the guideline asks for and whether it is met. As a guideline, open-flued appliances up to 35 kW need 4 m³ per kW in a room with a window or door to the outside, an air network with other rooms, or an opening to the outside of 150 cm²; a gas cooker up to 11 kW a room over 15 m³ with a window or door to the outside.

  • Put a Vent into a wall like a window (under Building services); its Free area (cm²) is in its properties.
  • For an air network switch on Door with a vent grille on a door (from 150 cm²).
  • For a cooker hood or a tumble dryer switch on Extract air to the outside; next to an open-flued gas appliance RoomPlanning then asks for a safety device.

11. Liquefied gas

Under Add network or the pressure stage pick Liquefied gas 50 mbar. LPG is heavier than air; an appliance or pipe in a room whose floor lies more than 1 m below the terrain everywhere gets a hint.

12. Print the plan, material list and line suggestion

In Gas plans and lists (with gas pipe, gas riser and flue) Print gas installation plan prints the storey's plan with legend, the stamp "Sketch – not a construction design" and the safety notice. A DXF export puts gas pipes, concealed gas pipes, fittings, appliances, flues and vents on layers of their own. Wall views show gas pipes with their heights.

With Premium you also get:

  • the Gas material list: metres per material and size with allowance (whole metres), bends, tees, transitions, fittings, wall and slab penetrations, pipe clips, appliances with kW, the flues and the connection values with flow and meter suggestion – as CSV for Excel or LibreOffice and to print;
  • Suggest a gas line on a selected gas appliance: a line from the meter at right angles along the walls, not through doors, windows and shafts, which you change freely afterwards.

AI assistants with RoomPlanning Connect lay gas appliances, pipes and flues as a sketch too and name the open hints.

If you smell gas

  • Do not use switches, doorbells or phones in the house, and no open flames.
  • Open windows and doors, close the main shut-off device.
  • Leave the house and warn everyone in it.
  • Call the network operator's emergency service from outside (the number is on the meter or on your bill); if there is danger, call 112.

Good to know

  • RoomPlanning does not size pipes and approves nothing. The installer sets the diameter according to the TRGI.
  • The material list counts all appliances at once (the safe side) and has no prices.

More guideline values on how a gas installation is built, on materials and appliance types are in Plan gas pipes. Water and drains are covered in Plan water and drains.