How many network sockets per room? Table and calculator
Last updated: 15 November 2026
Try it right away
Free in the browser; try it without an account. To save, export and share, create a free account.Under the German standard DIN 18015-2, every living room, bedroom, dining room and kitchen needs at least one connection for phone or data, a study two, and a living room over 20 m² two as well. The standard equipment of the guideline RAL-RG 678 adds one in the hallway, on the terrace and in the hobby room. Today you plan one double socket with two ports per connection, and two double sockets in the living room, for the TV wall and the sofa. A family house with six rooms comes to about 8 double sockets with 16 ports, plus ports for access points and cameras. All numbers here are guideline values; other countries have their own rules.
For your own home the network sockets calculator adds it all up, from the room to the network cabinet.
Connections per room under DIN 18015-2 and RAL-RG 678
First number: connections for phone and data. Second number: connections for radio and TV (antenna sockets). Minimum is the minimum equipment of DIN 18015-2:2021-10 (one star), standard and comfort are equipment levels 2 and 3 of RAL-RG 678:2023.
| Room | Minimum (★) | Standard (★★) | Comfort (★★★) |
|---|---|---|---|
| living room up to 20 m² | 1 / 1 | 1 / 2 | 1 / 2 |
| living room over 20 m² | 2 / 2 | 2 / 3 | 2 / 3 |
| bedroom, child's, guest room up to 16 m² | 1 / 1 | 1 / 1 | 1 / 2 |
| bedroom, child's, guest room over 16 m² | 1 / 1 | 2 / 1 | 2 / 2 |
| study | 2 / 0 | 2 / 1 | 2 / 2 |
| dining room or area | 1 / 1 | 1 / 1 | 1 / 1 |
| kitchen | 1 / 0 | 1 / 1 | 1 / 1 |
| bathroom | 0 / 0 | 0 / 0 | 1 / 1 |
| hallway | 0 / 0 | 1 / 0 | 1 / 0 |
| hobby room | 0 / 0 | 1 / 1 | 1 / 1 |
| terrace, balcony, loggia | 0 / 0 | 1 / 1 | 1 / 1 |
| WC, utility room, storeroom, cellar | 0 / 0 | 0 / 0 | 0 / 0 |
The standard counts connections, not sockets and not ports. Whether a connection becomes a single or a double network socket is left open. The full standards are only available for a fee; the values above follow the HEA summary and manufacturers' documents.
Recommendation: double sockets per room
This table is RoomPlanning's own recommendation after common practice of electricians and network planners, not part of the standard. It comes on top of the table above: every room gets at least as many double sockets as the standard has connections.
| Where | Recommendation (guideline value) |
|---|---|
| living room | 2 double sockets: at the TV wall (TV, receiver, console) and opposite or at the sofa |
| study | 1 double socket per workplace, at least 2 |
| bedroom, child's room | 1 double socket at the desk or TV |
| kitchen and dining room | 1 double socket each (display, radio, appliance) |
| hobby room | 1 double socket |
| ceiling, per access point | 1 port with PoE |
| technical and outdoors | 1 port per camera, IP door station, inverter, heat pump, wallbox or smart meter gateway |
| spare at the patch panel | 20 to 25% on the ports in use, rounded up to 12, 24 or 48 ports |
Under DIN 18015-3 data sockets usually sit 30 cm above the floor, like the power sockets next to them. Plan a power socket beside every network socket, because nearly every wired device needs power too.
Access points, cameras and PoE
For Wi-Fi the rule of thumb is one access point per storey and about 60 to 100 m², less area per device with solid walls. Access points go on the ceiling, in the middle of the area they serve, and get their power over the network cable (Power over Ethernet, PoE). This estimate does not replace a measurement on site.
| PoE standard (IEEE 802.3) | Power at the device |
|---|---|
| 802.3af (PoE) | 12.95 W |
| 802.3at (PoE+) | 25.5 W |
| 802.3bt | 51 or 71 W |
Guideline values per device: access point 10 to 20 W, camera 5 to 13 W, IP door station 6 to 13 W. The switch's PoE budget is the sum of all devices plus about 20% reserve.
Patch panel, switch and network cabinet
A home network is a star: every socket gets its own cable to the patch panel in the distributor. The distributor is a flush-mounted media distributor or a network cabinet (10 or 19 inch), usually in the utility or technical room or centrally in the hallway. It needs power, best on a circuit of its own, and ventilation.
| In the network cabinet | Rack units (U) |
|---|---|
| patch panel | 1 per 24 ports |
| switch | 1 |
| cable management | 1 |
| router and fibre modem on shelf | 1 to 2 |
| power strip | 1 |
| reserve | 2 |
A family house with 24 ports so comes to about 9 U. Wall cabinets usually have 6 to 12 U.
Cable: Cat 7 installation cable and Cat 6A sockets
- In German home building, Cat 7 usually names the installation cable (S/FTP, 600 MHz; Cat 7A 1000 MHz). Sockets and patch panels with RJ45 only go up to Cat 6A. Together the link reaches class EA, that is 10 Gbit/s.
- The permanent link may be at most 90 m long, with patch cords at most 100 m. In a family house this is practically never reached.
- Data and power cables on parallel routes need some distance. With shielded cable it is small, separate conduits are common all the same.
- Cable, roughly: the horizontal run to the distributor plus the verticals, 2 m slack at the distributor and 0.3 m at the socket, all times 1.1 for waste. It comes in reels of 100 or 500 m.
Worked example: family house with 140 m²
Standard equipment (two stars), two storeys, two cameras and two more devices such as a door station and an inverter. The calculator counts the same way and starts with these values.
| Room | Standard data / TV | Double sockets | Ports |
|---|---|---|---|
| living room, 30 m² | 2 / 3 | 2 | 4 |
| kitchen | 1 / 1 | 1 | 2 |
| bedroom, 14 m² | 1 / 1 | 1 | 2 |
| child's room, 12 m² | 1 / 1 | 1 | 2 |
| study | 2 / 1 | 2 | 4 |
| hallway, 6 m long | 1 / 0 | 1 | 2 |
| total | 8 / 7 | 8 | 16 |
Add 2 access points (one per storey of 70 m²), 2 cameras and 2 devices: 22 ports in use. With 25% spare that is 28, so one patch panel with 48 ports. The switch needs 24 ports, one of them to the router. The PoE budget is about 60 W (2 × 15 W and 2 × 10 W plus 20%). The network cabinet needs 9 U. Installation cable comes to roughly 400 m, so one reel of 500 m.
Planning the network in RoomPlanning
In RoomPlanning you place network sockets, patch panel, network cabinet, router, access points and satellite connections on a layer of their own in the floor plan and draw the data cables to the distributor. A check compares each room with the equipment levels from the table above. How it works is in Plan network and smart home and in the help Network and smart home. The power sockets are in the guide How many sockets per room?.
Frequently asked questions
How many network sockets does a living room need?
Under DIN 18015-2 one data connection up to 20 m², two above. Two double sockets are recommended, one at the TV wall and one opposite or at the sofa, so 4 ports.
How many network sockets does a study need?
The standard gives two connections on all three equipment levels. Plan one double socket per workplace, at least two.
Does every bedroom need a network socket?
Under DIN 18015-2 yes, at least one connection for phone or data. Plan a double socket at the desk or TV.
How big does the patch panel need to be?
As big as the ports in use plus 20 to 25% spare, rounded up to 12, 24 or 48 ports. A patch panel with 24 ports takes 1 U.
Do I need network sockets if I have Wi-Fi?
Yes. Access points need a cable themselves, and TVs, consoles, workplaces and cameras run more reliably on a cable. Adding cables to finished walls later is a lot of work, so it pays to plan them right away.
Sources
- Installation scope and equipment levels (German) – Baunetz Wissen
- RAL-RG 678, summary (PDF, 2023, German) – HEA
- Press release on RAL-RG 678, 20 March 2023 (PDF, German) – HEA
- Twisted pair cable, categories (German) – Wikipedia
- Power over Ethernet (German) – Wikipedia
- Installation zone (German) – Wikipedia
This guide is general information with guideline values and does not replace planning by a qualified electrician.