Backwater level and lifting units in the basement
Last updated: 16 November 2026
Try it right away
Free in the browser; try it without an account. To save, export and share, create a free account.The backwater level is the height up to which waste water from the public sewer can push back into the house drains in heavy rain. Your municipality sets it in its drainage statute; without one the street surface at the connection counts (DIN EN 12056-4). Every outlet below it, usually everything in the basement, must be protected against backflow: as a rule by a lifting unit that pumps the waste water through a loop above the backwater level into the sewer.
Lifting unit or backwater valve?
- Lifting unit (DIN EN 12050-1): the usual case for outlets below the backwater level, always for waste water with faeces (a WC in the basement). Its pressure pipe loops above the backwater level before it joins the ground pipe.
- Backwater valve (DIN EN 13564): only allowed as an exception: there is a fall to the sewer, the rooms are of minor use (no living rooms), few people use them and a WC above the backwater level is available. A backwater valve stays shut while the backflow lasts; nothing can drain from the basement then.
What belongs in the plan?
For a drainage application the longitudinal section of the ground pipe shows the backwater level as a line, with the inverts of the pipes and the chambers. In the riser diagram it runs dashed above all outlets that lie lower.
Planning backflow protection with RoomPlanning
In RoomPlanning you set the backwater level under Water and drainage; without a height of your own the ground at the house counts. A hint reports every outlet below it without a lifting unit or backwater valve. With Premium the riser diagram and the section show the backwater level, and the sheet Drainage application puts the documents together (Plan water and drains).

Detached house with basement
228.1 m² · 17 rooms
Frequently asked questions
Where is the backwater level?
Your municipality decides; mostly it is the street surface where your house joins the sewer. Ask the public works or the drainage utility.
Does a basement floor drain need a lifting unit?
If it lies below the backwater level, yes, or a backwater valve in the exceptions named above. Without protection, waste water from the sewer can flood the basement in heavy rain.
May I connect a basement WC through a backwater valve?
No, waste water with faeces below the backwater level needs a lifting unit for faecal water after DIN EN 12050-1.
Sources
- Backflow protection leaflet (PDF, German) – StEB Köln
- Backflow (German) – Hamburg.de
- Waste pipes: sizing and nominal sizes (German) – Baunetz Wissen
This guide is general information and does not replace planning by a specialist; your municipality's drainage statute decides.