Networking a new build: Cat 7, patch panel, media enclosure, Wi-Fi
Last updated: 16 November 2026
Try it right away
Free in the browser; try it without an account. To save, export and share, create a free account.A home network in a new build is a star: every network socket gets its own Cat 7 installation cable to the patch panel in the media enclosure or network cabinet. Sockets and patch panel use Cat 6A modules, so the link carries 10 Gbit/s. A permanently installed link may be at most 90 m long. Wi-Fi comes from access points on the ceiling, about one per storey and 60 to 100 m², powered over the network cable (PoE). The fibre connection ends in the house connection room and runs on through the fibre socket and ONT to the router. All numbers here are guideline values, mostly after German and European standards; the installation is a job for a qualified electrician.
How many sockets each room needs is in the guide How many network sockets per room?; the network sockets calculator works it out for your whole home.
Topology: a star to the distributor
Unlike power sockets, network sockets are not chained on one cable. Every socket gets a cable of its own, and all cables end in one place: the patch panel. From there short patch cords connect the ports to the switch, the switch to the router. So you can later use any socket for anything: a computer, TV, access point or camera.
| Limit (EN 50173-1, ISO/IEC 11801) | Length |
|---|---|
| permanently installed link (permanent link) | up to 90 m |
| channel with patch cords at both ends | up to 100 m |
A family house practically never gets near that. More important is a central distributor, so the runs stay short.
Cable: Cat 7 installation cable and Cat 6A sockets
- Cat 7 is the usual name in German housing for the installation cable: S/FTP, every pair and the whole cable shielded, 600 MHz, as Cat 7A 1000 MHz.
- Sockets and patch panels with RJ45 only go up to Cat 6A. Together the link reaches class EA and thus 10GBASE-T. There is no "Cat 7 socket" with RJ45.
- Distance from power: for parallel runs of data and power cables EN 50174-2 sets minimum distances. With shielded cable they are small; separate conduits or trunking are common all the same.
- Conduits: one conduit per socket or a large conduit to the distributor makes pulling new cables easy later.
| Category | Bandwidth | Typical use in the house |
|---|---|---|
| Cat 6A | 500 MHz | sockets, patch panel, patch cords; 10 Gbit/s |
| Cat 7 (installation cable) | 600 MHz | cable in walls and ceilings |
| Cat 7A (installation cable) | 1000 MHz | cable in walls and ceilings, more headroom |
Where the cables run: installation zones
So that nobody drills into a cable later, cables run in fixed zones after the German DIN 18015-3 (guideline values):
| Zone | Position |
|---|---|
| horizontal top | 15 to 45 cm below the ceiling, preferred 30 cm |
| horizontal bottom | 15 to 45 cm above the floor, preferred 30 cm |
| middle zone (kitchen, worktops) | 100 to 130 cm above the floor, preferred 115 cm |
| vertical | 10 to 30 cm beside doors, windows and corners |
| box height | data and power sockets 30 cm, switches 105 cm |
Cable quantity, roughly: horizontal run to the distributor plus the verticals, 2 m reserve at the distributor and 0.3 m at the socket, all times 1.1 for waste. You buy it in rings of 100 or 500 m.
Media enclosure or network cabinet
The distributor is a flush-mounted media enclosure or a network cabinet of 10 or 19 inches, as a wall cabinet usually 6 to 12 rack units (U). Typical places are the house connection or technical room, where fibre and power arrive, or centrally in the hall. It needs 230 V, best on a circuit of its own, and ventilation, because switch and router get warm.
| In the network cabinet | Rack units (U) |
|---|---|
| patch panel | 1 per 24 ports |
| switch | 1 |
| cable management | 1 |
| router and ONT on a shelf | 1 to 2 |
| power strip | 1 |
| reserve | 2 |
A family house with 24 ports comes to about 9 U. Plan the patch panel with 20 to 25 % spare on the used ports, rounded up to 12, 24 or 48 ports.
Fibre (FTTH) and § 145 TKG
Inside the house the fibre runs like this (network level 4):
- Building entry point in the house connection room (German DIN 18012);
- fibre socket in the dwelling;
- ONT or fibre modem, then the router, best both in the media enclosure.
The network operator sets how many fibres reach each dwelling; as a guideline 2 to 4.
In Germany, § 145 (4) TKG requires new buildings with end-user connections to have a passive, high-speed-ready in-building network infrastructure up to the network termination points and an access point. Single-family houses are exempt under para. 6; a conduit from the house connection to the distributor is still a good idea. The EU tightens this with the Gigabit Infrastructure Act (Regulation (EU) 2024/1309, Art. 10) towards fibre readiness for building permits from 12 February 2026; the German implementation was still a draft when this was written.
Wi-Fi: access points instead of a router in the basement
A router in the basement rarely covers the whole house. Access points on the ceiling do better, in the middle of the area they serve, each with its own network cable.
- Rule of thumb: one access point per storey and about 60 to 100 m², fewer square metres per device in solid masonry.
- Signal: good from −67 dBm (video, calls), −67 to −75 dBm enough, weak below.
- Walls and slabs dampen the signal, more at 5 GHz than at 2.4 GHz:
| Wall | 2.4 GHz | 5 GHz |
|---|---|---|
| plasterboard, drywall | 3–4 dB | 4–6 dB |
| masonry (brick, sand-lime) | 8–12 dB | 10–18 dB |
| concrete, reinforced concrete | 10–20 dB | 15–32 dB |
| metal, lift shaft | 10–30 dB | 20–40 dB |
Transmit power is limited in the EU: 2.4 GHz 100 mW (20 dBm), 5.15 to 5.35 GHz 200 mW (23 dBm, indoors only), 5.47 to 5.725 GHz 1 W (30 dBm). An estimate from the floor plan does not replace a measurement on site, but shows early where an access point is missing.
PoE: power over the network cable
Access points, cameras and IP door stations get their power over the network cable (Power over Ethernet), so no power socket is needed on the ceiling.
| PoE standard (IEEE 802.3) | Power at the device |
|---|---|
| 802.3af (PoE) | 12.95 W |
| 802.3at (PoE+) | 25.5 W |
| 802.3bt | 51 or 71 W |
Guideline values per device: access point 10 to 20 W, camera 5 to 13 W, IP door station 6 to 13 W. The switch's PoE budget is the sum of all devices plus about 20 % reserve.
Checklist for the new build
- A central distributor with 230 V, ventilation and room to spare (guideline 9 U for 24 ports).
- A conduit from the house connection room to the distributor for fibre and cable TV.
- A double socket per connection, two in the living room, one per desk in the study.
- At least one ceiling outlet with a network cable per storey for an access point.
- Cables for cameras, door station, inverter, heat pump and wallbox planned straight away.
- A riser point or shaft between the storeys with room for all cables.
- Label patch panel and sockets right away, for example "GF-ST-01", and keep a patch list.
Planning the network in RoomPlanning
In RoomPlanning you place network sockets, media enclosure, patch panel, access points and riser points on your floor plan and draw the cables as a star to the distributor, across several storeys too. Suggest network places sockets, distributor and cables for the whole house in one step, and the bill of materials counts cable metres with rings, patch panel, switch and PoE. With Premium, RoomPlanning estimates the Wi-Fi coverage as a heatmap and exports the bill of materials and patch list. How it works is on Plan a network and in the help Plan a network.

Detached house 140 m² with network
143.4 m² · 13 rooms
Frequently asked questions
Is Cat 6A enough or does it have to be Cat 7?
For sockets and patch panel there is only Cat 6A with RJ45 anyway. As installation cable Cat 7 is common in German housing because it costs hardly more and has more headroom. A plain Cat 6A installation cable with Cat 6A sockets reaches 10 Gbit/s too.
How long may a network cable in the house be?
The permanently installed link from socket to patch panel at most 90 m, with the patch cords at both ends at most 100 m. A family house stays far below that.
Media enclosure or network cabinet?
A flush-mounted media enclosure fits in the wall and is enough for patch panel, a small switch and router. A 19-inch network cabinet has more room for a PoE switch, patch panels and reserve. With 24 ports and reserve a house comes to about 9 U.
How many access points does a family house need?
As a rule of thumb one per storey and about 60 to 100 m², more in solid masonry. A house with two storeys and 140 m² usually manages with two or three. Where exactly, an estimate from the floor plan or a measurement shows.
Do I have to run fibre into a single-family house?
Not under German law: single-family houses are exempt from § 145 (4) TKG. A conduit from the house connection to the distributor is still worth it, so the operator can pull the fibre in later.
Sources
The values are guideline values from freely available sources; the standards themselves are paid. Read on 16 November 2026:
- Twisted-Pair-Kabel, Kategorien – Wikipedia (German)
- Installationszone – Wikipedia (German)
- Power over Ethernet – Wikipedia (German)
- § 145 TKG – Gesetze im Internet (German)
- Regulation (EU) 2024/1309 (Gigabit Infrastructure Act) – EUR-Lex
- Die zentralen Neuerungen des TKG-E 2026 – Grant Thornton (German)
- Whitepaper WLAN-Ausleuchtung (PDF, 2024) – Michael Wessel (German)
- WLAN-Ausleuchtung (PDF, 2024) – D-Link (German)
- ITU model for indoor attenuation – Wikipedia
This guide is general information with guideline values and does not replace planning by a qualified electrician.