Planning a plumbing installation: connection heights, slope, pipe sizes

Last updated: 16 November 2026

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan

You plan a plumbing installation in three steps: first decide where washbasin, WC, shower and sink go and at which height their connections sit. Then run cold and hot water and the waste water to the nearest riser, the waste water with at least 1 % slope. Finally size the pipes: drinking water from the loading units of the taps, waste water from their discharge units. All figures here are guideline values; in Germany only a registered plumbing contractor may build a drinking water installation (§ 12 AVBWasserV).

Connection heights

Usual heights above the finished floor (axis, the manufacturer's data come first):

FixtureCold and hot waterWaste
Washbasinabout 550 mm, hot left, cold rightabout 500–550 mm, DN 40
Wall-hung WC with framecistern about 1,050–1,150 mmaxis about 230 mm, DN 90/100
Showermixer about 1,100–1,200 mmin the floor, DN 50
Bathtubabout 150–200 mm above the rimat the foot of the tub, DN 50
Kitchen sink, dishwasherangle valves about 500–550 mmabout 450–500 mm, DN 50
Washing machineappliance valve about 1,000–1,200 mmtrap about 600–900 mm

Slope and ventilation

Waste pipes fall in the direction of flow: unvented branch pipes at least 1 %, horizontal pipes in the building at least 0.5 % (DIN 1986-100). An unvented single branch should be no longer than about 4 m, have at most three bends and fall at most about 1 m; beyond that it needs a vent or an air admittance valve. Every stack is vented above the roof.

Pipe sizes as a guideline

  • Drinking water: every tap has a loading unit (LU) after DIN EN 806-3: washbasin and WC 1, shower, sink, washing machine and dishwasher 2, bathtub 4. Their sum gives the peak flow, and from it the smallest pipe in which water flows no faster than about 2 m/s. A bathroom with washbasin, WC and shower (4 LU) gets by with multilayer pipe 20×2.
  • Waste water: every outlet has a discharge unit (DU) after DIN EN 12056-2: washbasin 0.5, shower 0.6, bathtub and sink 0.8, WC 2.0 l/s. The flow is Qww = 0.5·√ΣDU in housing, at least the largest single unit. With a WC the pipe is at least DN 100; ground pipes are at least DN 100.

Check both with the pipe size calculator and the waste pipe DN calculator.

Planning plumbing with RoomPlanning

In RoomPlanning the fixtures bring their connections along. You draw pipes with their height in wall, floor or ceiling, waste pipes with a slope, and risers through all storeys (Plan water and drains). With Premium RoomPlanning works out the guideline size of every section, makes the material list and the riser diagram and connects a bathroom automatically if you like.

Detached house with building services in 3D, seen from above at an angle, furnished

Detached house with building services

228.1 m² · 17 rooms

Frequently asked questions

How high are the water connections at a washbasin?

About 550 mm above the finished floor, hot left and cold right, about 150–200 mm apart. The waste sits at about 500–550 mm. The installation instructions of the basin and the mixer decide.

How much slope does a bathroom waste pipe need?

At least 1 % for unvented branch pipes, so 1 cm per metre. Horizontal collecting and ground pipes in the building need at least 0.5 %.

Which diameter does the bathroom water pipe have?

As a guideline, multilayer pipe 20×2 or copper 18×1 serves a bathroom with washbasin, WC and shower, 16×2 or 15×1 a single tap. With a bathtub or several bathrooms the supply pipe gets larger.

Sources

This guide is general information with guideline values from freely available sources and does not replace planning by a registered plumbing contractor.