How many sockets per room? Table to DIN 18015-2

Last updated: 13 November 2026

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan

Under the German standard DIN 18015-2, edition 2021, a living room up to 20 m² needs at least 4 sockets and 3 more for phone, router and TV, a bedroom up to 16 m² 6 sockets and 2 for media. The kitchen has 3 general sockets, 2 per 1.20 m of worktop and one each for the fridge, the cooker hood and phone or data. The bathroom needs at least 2. That is the minimum. Above it, the guideline RAL-RG 678 describes standard and comfort equipment with considerably more sockets, up to 10 plus 8 in the living room.

Minimum, standard and comfort

DIN 18015-2 sets what a home must have at least. The guideline RAL-RG 678 takes this minimum as equipment level 1 (one star) and adds level 2 (standard, two stars) and 3 (comfort, three stars). Many German developers and electricians describe their offers with these stars. Other countries have their own rules.

Sockets per room

First number: general sockets. Second number: sockets for phone, router, TV and similar devices. As of DIN 18015-2:2021-10 and RAL-RG 678:2023.

RoomMinimum (★)Standard (★★)Comfort (★★★)
living room up to 20 m²4 + 38 + 410 + 8
living room over 20 m²5 + 511 + 813 + 12
bedroom, child's, guest room up to 16 m²6 + 28 + 310 + 4
bedroom, child's, guest room over 16 m²8 + 211 + 613 + 8
study4 + 48 + 612 + 8
dining room or area3 + 35 + 37 + 4
kitchen (plus worktop and appliances)3 + 13 + 25 + 3
bathroom245 + 3
WC122
hallway up to 4 m long12 + 13 + 2
hallway over 4 m long23 + 14 + 2
utility room268
hobby room36 + 28 + 2
storeroom122
cellar, loft, garage122
terrace, balcony, loggia12 + 23 + 3

In the kitchen add: 2 sockets per 1.20 m of worktop (standard and comfort: 3), sockets for fridge and freezer (1, otherwise 2) and one for the cooker hood. The utility room gets one socket per 1.20 m of worktop and one for a fridge or freezer.

A circuit of its own applies on all three levels to the electric cooker, microwave or steam oven, dishwasher, washing machine, tumble dryer and, where there is one, a water heater, a heater in the bathroom and an electric car charger. These connections are not counted in the sockets above.

For a single room the sockets calculator adds everything up.

How it is counted

  • Every socket counts on its own. The 2021 edition simplified the counting, so a double socket counts as two. Older editions counted a double socket at the bed or the worktop as one. That is why many websites still give smaller numbers.
  • Combined areas: if living and dining are in one room, the general sockets may be one fewer per area.
  • At the bed: every bed place gets its own switch and two sockets.
  • Rooms not in the table need at least one light point, one switch and one socket.

Light points

RoomMinimumStandardComfort
living room up to / over 20 m²1 / 22 / 33 / 4
bedroom up to / over 16 m²1 / 22 / 33 / 4
kitchen233
bathroom233
hallway up to / over 4 m1 / 22 / 22 / 2

Circuits

For lights and general sockets DIN 18015-2 gives the number of circuits by floor area. The circuits for the cooker, dishwasher and the other appliances come on top.

Floor areaCircuits for lights and sockets
up to 50 m²3
over 50 to 75 m²4
over 75 to 100 m²5
over 100 to 125 m²6
over 125 m²7

With standard and comfort equipment every living room and bedroom, the kitchen, bathroom, utility room, cellar and outdoor seating area gets a circuit of its own, with comfort the hallway too.

Worked example: two-room apartment of 55 m²

Two-room apartment 55 m² in 3D, seen from above at an angle, furnished

Two-room apartment 55 m²

54.9 m² · 5 rooms

Minimum equipment for the template above:

RoomSocketsHow
living room, 19.2 m²74 general + 3 for media
bedroom, 12.7 m²86 general + 2 for media
kitchen, assuming 2.40 m of worktop103 general + 2 × 2 worktop + 1 media + fridge + cooker hood
bathroom2
hallway, 4.2 m long2hallway over 4 m
balcony1
total30

On top come circuits of their own for the cooker, dishwasher and washing machine, and 4 circuits for lights and sockets, because the apartment is between 50 and 75 m².

Planning sockets in RoomPlanning

In the RoomPlanning electrical plan you place sockets, switches and ceiling outlets in the floor plan, set up circuits and draw the cables. The legend counts the symbols on every circuit and the length of its cables. That way you quickly check whether each room reaches the number in the table. How it works and where the sockets go is explained in Creating an electrical plan.

Frequently asked questions

How many sockets does a living room need?

Up to 20 m² at least 4 general and 3 for phone, router and TV, so 7. Over 20 m² it is 5 and 5. For standard equipment plan 8 and 4.

How many sockets does a bedroom need?

Up to 16 m² at least 6 and 2 for media, over 16 m² 8 and 2. Plan two of them at each bed place.

How many sockets does a kitchen need?

3 general, 2 per 1.20 m of worktop, and one each for the fridge, cooker hood and phone or data. With 2.40 m of worktop that makes 10. The cooker, dishwasher and microwave get their own connections.

Does a double socket count as one or two?

Since DIN 18015-2:2021 as two, because the table counts every socket on its own.

Sources

This guide is general information and does not replace planning by a qualified electrician.

Matching templates

Try it right away

Free in the browser; try it without an account. To save, export and share, create a free account.
Start a floor plan